International Journal of Clinical Pediatric Dentistry

Register      Login

VOLUME 17 , ISSUE 10 ( October, 2024 ) > List of Articles

CASE REPORT

Operational Distal Shoe Appliance for Harmonious Occlusion: A Case Report

Abinash Mohapatra, Sharbari Dutta, Brahmananda Dutta, Aditi Gupta

Keywords : Case report, Distal shoe, Functional appliance, Permanent first molar, Primary molars

Citation Information : Mohapatra A, Dutta S, Dutta B, Gupta A. Operational Distal Shoe Appliance for Harmonious Occlusion: A Case Report. Int J Clin Pediatr Dent 2024; 17 (10):1172-1175.

DOI: 10.5005/jp-journals-10005-2964

License: CC BY-NC 4.0

Published Online: 27-11-2024

Copyright Statement:  Copyright © 2024; The Author(s).


Abstract

Preserving deciduous teeth till their natural exfoliation is important to maintain arch length in different dentition periods. Premature loss of primary teeth may cause discrepancy in arch length due to drifting of teeth and supraeruption of the opposite teeth, thereby hindering the development of a harmonious, functionally and esthetically acceptable dentition. This article describes the fabrication and clinical application of a modified functional distal shoe appliance used due to pathological obliteration of the primary/deciduous mandibular second molar prior to the eruption of the permanent mandibular first molar. This modified functional intra-alveolar space maintainer appliance not only guides the first permanent molar eruption but also prevents ectopic eruption of the second premolar and supra-eruption of the second maxillary primary molar.


PDF Share
  1. Srivastava N, Grover J, Panthri P. Space maintenance with an innovative “tube and loop” space maintainer (Nikhil appliance). Int J Clin Pediatr Dent 2016;9(1):86–89. DOI: 10.5005/jp-journals-10005-1340
  2. Nayak UA, Loius J, Sajeev R, et al. Band and loop space maintainer—made easy. J Indian Soc Pedod Prev Dent 2004;22(3):134–136.
  3. Graber TM. Preventive orthodontics. Orthodontics Principles and Practice, 3rd edition. Philadelphia: WB Saunders Company; 1972. pp. 627–667.
  4. Jeffry A. Management of the developing occlusion. In: McDonald RE, Avery DR (Eds). Dentistry for the Child and Adolescent, 8th edition. Philadelphia: Harcourt India Private Limited; 2001. pp. 625–683.
  5. Gujjar KR, Indushekar KR, Amith HV, et al. Modified distal shoe appliance—fabrication and clinical performance. J Dent Child 2012;79(3):185–188.
  6. Bhat PK, Navin HK, Idris M, et al. Modified distal shoe appliance for premature loss of multiple deciduous molars: a case report. J Clin Diagn Res 2014;8(8):ZD43–ZD45. DOI: 10.7860/JCDR/2014/9796.4759
  7. Brill WA. The distal shoe space maintainer chairside fabrication and clinical performance. Pediatr Dent 2002;24(6):561–565.
  8. Anegundi RT, Banerjee S, Patil SB, et al. A modification of distal shoe appliance for premature loss of primary second molar-comparison with Willet's appliance: report of four cases. Int J Pedod Rehabil 2019;4(2):84. DOI: 10.4103/ijpr.ijpr_9_19
  9. Somwanshi YI, Katre AN, Jawdekar AM. Modified distal shoe appliance for multiple loss of first and second primary molars. J Clin Diagn Res 2016;10(10):ZJ03–ZJ04. DOI: 10.7860/JCDR/2016/17686.8660
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.