Sneha S, Kumar SS, Annamalai I, Rathi SS, Priya RS. The Effect of Light-emitting Diode Light Intensities and Duration of Cure on Pulpal Wall Temperature among Different Classes of Teeth. Int J Clin Pediatr Dent 2024; 17 (4):467-471.
Introduction: The thermal changes during light curing of resin-based composites (RBCs) are recognized, but there is a lack of information about temperature changes in pulp tissue under different curing protocols, especially during bonding of orthodontic brackets onto the tooth surface. In the present study, pulpal temperature (PT) variation induced by the use of four different light cure intensities and different durations of cure among different classes of teeth was measured.
Materials and methods: A total of 80 different classes of human extracted teeth (maxillary and mandibular central incisor, lateral incisor, canine, premolar, and molar) were irradiated at the same distances with four visible light curing intensities. Brackets (3M Unitek) were bonded with Transbond XT (3M Unitek, Monrovia, California) adhesive and light cured with a light-emitting diode (LED) light cure unit (LCU) (Bluephase). A J-type thermocouple wire was positioned in the center of the pulp chamber to assess the temperature difference. The results were analyzed with analysis of variance (ANOVA) and the Tukey's honestly significant difference (HSD) test.
Results: Light-emitting diode with higher intensity induced significantly higher intra-PT changes than did the LED with lower intensity (p < 0.001). Mandibular central incisors had the highest intra-PT of about 45°C at 3000 mW/cm2, 3 seconds. Maxillary central incisors had the highest intra-PT of about 40°C at 3000 mW/cm2, 3 seconds. Mandibular and maxillary canines and molars had the lowest intra-PT of about 10°C at 800 mW/cm2, 20 seconds.
Conclusion: Pulp chamber temperature changes were influenced by the intensity and duration of curing and the anatomy of the tooth (class/type of tooth).
Ward JD, Wolf BJ, Leite LP, et al. Clinical effect of reducing curing times with high-intensity LED lights. The Angle Orthodontist 2015;85(6):1064–1069. DOI: 10.2319/080714-556.1
Gupta SP, Shrestha BK. Shear bond strength of a bracket-bonding system cured with a light-emitting diode or halogen-based light-curing unit at various polymerization times. Clin Cos Invest Dent 2018;10:61–67. DOI: 10.2147/CCIDE.S155829
Kapdan A, Kaya S, Eren D. Influence of different led curing-units on depth of cure and micro-hardness of nano-hybrid resin composite. Cumhuriyet Dent J 2021;24(1):88–95. DOI: 10.7126/cumudj.855065
Mavropoulos A, Staudt CB, Kiliaridis S, et al. Light curing time reduction: in vitro evaluation of new intensive light-emitting diode curing units. Eur J Orthod 2005;27(4):408–412. DOI: 10.1093/ejo/cji021
Sunna S, Rock WP. Clinical performance of orthodontic brackets and adhesive systems: a randomized clinical trial. Br J Orthod 1998;25(4):283–287. DOI: 10.1093/ortho/25.4.283
Chaukse A, Dubey R, Agrawal N, et al. A review of orthodontic curing lights. Indian J Stomatol 2013;4(1):40–44.
Knežević A, Tarle Z, Meniga A, et al. Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes. J Oral Rehabil 2001;28(6):586–591. DOI: 10.1046/j.1365-2842.2001.00709.x
Santini A, Watterson C, Miletic V. Temperature rise within the pulp chamber during composite resin polymerisation using three different light sources. Open Dent J 2008;2:137–141. DOI: 10.2174/1874210600802010137
Daronch M, Rueggeberg FA, Hall G, et al. Effect of composite temperature on in vitro intrapulpal temperature rise. Dent Mater 2007;23(10):1283–1288. DOI: 10.1016/j.dental.2006.11.024
Palomares NB, Cal-Neto JP, Sampaio-Filho H, et al. Effect of high-intensity LED units at reduced curing time on in vitro bond strength of orthodontic brackets. World J Orthod 2008;9(3):203–208.
Lin M, Xu F, Lu TJ, et al. A review of heat transfer in human tooth–experimental characterization and mathematical modeling. Dent Mater 2010;26(6):501–513. DOI: 10.1016/j.dental.2010.02.009
Uzel A, Buyukyilmaz T, Kayalioglu M, et al. Temperature rise during orthodontic bonding with various light-curing units-an in vitro study. Angle Orthod 2006;76(2):330–334. DOI: 10.1043/0003-3219(2006)076[0330:TRDOBW]2.0.CO;2
Vinagre A, Ramos JC, Rebelo C, et al. Pulp temperature rise induced by light-emitting diode light-curing units using an ex vivo model. Materials 2019;12(3):411. DOI: 10.3390/ma12030411
Ozturk B, Ozturk AN, Usumez A, et al. Temperature rise during adhesive and resin composite polymerization with various light curing sources. Oper Dent 2004;29(3):325–332.
Malkoç S, Uysal T, Üşümez S, et al. In-vitro assessment of temperature rise in the pulp during orthodontic bonding. Am J Orthod Dentofacial Orthop 2010;137(3):379–383. DOI: 10.1016/j.ajodo.2008.02.028
Zach L, Cohen G. Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 1965;19(4):515–530. DOI: 10.1016/0030-4220(65)90015-0
Cantekin K, Buyuk SK, Delikan E, et al. Pulp chamber temperature increase from curing light units: an in vitro study. J DentChild (Chic) 2014;81(3):128–132.
Uysal T, Eldeniz AU, Usumez S, et al. Thermal changes in the pulp chamber during different adhesive clean-up procedures. Angle Orthod 2005;75(2):216–221. DOI: 10.1043/0003-3219(2005)075<0216:TCITPC>2.0.CO;2
Palma-Dibb RG, Savaris C, Chinelatti MA, et al. Composite photo polymerization: temperature increase according to light source and dentin thickness. J DentOral Implants 2016;1(2):11–19. DOI: 10.14302/issn.2473-1005.jdoi-16-1080