International Journal of Clinical Pediatric Dentistry

Register      Login

VOLUME 7 , ISSUE 3 ( September-December, 2014 ) > List of Articles

RESEARCH ARTICLE

A Comparison of Canal-centering ability of Two Nickel-Titanium Rotary Systems with Nickel Hand Instrumentation with Stainless Steel Hand Instrumentation in 10 to 25° Curved Canals using Kuttler's Cube

Anupama Swarnkar

Keywords : Kuttler's endodontic case, Canal-centering ability, NiTi rotary instruments, Profile, Lightspeed (LSX)

Citation Information : Swarnkar A. A Comparison of Canal-centering ability of Two Nickel-Titanium Rotary Systems with Nickel Hand Instrumentation with Stainless Steel Hand Instrumentation in 10 to 25° Curved Canals using Kuttler's Cube. Int J Clin Pediatr Dent 2014; 7 (3):157-162.

DOI: 10.5005/jp-journals-10005-1256

License: CC BY-NC 4.0

Published Online: 01-12-2018

Copyright Statement:  Copyright © 2014; The Author(s).


Abstract

Aims: The purpose of this study was to compare the canal centering abilities of rotary nickel-titanium (NiTi) files (ProFile 0.04 and 0.06 and Lightspeed LSX) and NiTi hand K-files in 10° to 25° curved canals. This was compared with the canal centering ability of stainless steel hand K-files using Kuttler's endodontic cube. Settings and design: The teeth with a 10° to 25° of clinical mesiodistal curvature were used for this study. Each tooth was immersed in methylene blue dye for a period of 10 seconds, as recommended by Kuttler. Materials and methods: The study sample comprised of 60 intact freshly extracted single rooted human mandibular premolars. The radiographs were traced on a tracing paper and the canal curvature was determined according to methodology introduced by Schneider. Statistical analysis used: The statistical package SPSS PC + (Statistical package for social service, Version 4.01) was used for analysis. Results: Overall, Lightspeed LSX instruments showed superior canal centering ability and performed better than Profile series, hand NiTi K-files and hand stainless steel K-files. Conclusion: The endodontic cube can be used as an effective method for analyzing the canal-centering ability of different endodontic instruments. Both the NiTi rotary instruments showed superior canal-centering ability than NiTi and stainless steel hand K-files. How to cite this article: Swarnkar A. A Comparison of Canal-centering ability of Two Nickel-Titanium Rotary Systems with Nickel Hand Instrumentation with Stainless Steel Hand Instrumentation in 10 to 25° Curved Canals using Kuttler's Cube. Int J Clin Pediatr Dent 2014;7(3):157-162.


PDF Share
  1. Park H. A comparison of greater taper files, ProFiles and stainless steel files to shape curved root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2001;91:715-718.
  2. Cimis GM, Boyer TJ, Pelleu GB. Effect of three file types on the apical preparation moderately curved canals. J Endod 1988; 14:441-444.
  3. Yoshimine Y, Ono M, Akamine A. The shaping effects of three nickel-titanium rotary instruments in simulated S-Shaped canals. J Endod 2005;31:373-375.
  4. Bramante CM, Berbert A, Borger RP. A methodology for the evaluation of root canal instrumentation. J Endodont 1987; 14:273-277.
  5. Kuttler S, Garala Mand, Dorn RPSO. The endodontic cube: a system designed for evaluation of root canal anatomy and canal preparation. J Endodont 2001;27:533-536.
  6. Schneider SW. A comparison of canal preparation in straight and curved canals. Oral Surg 1971;32:271-275.
  7. Lodd Tharuni S, Parameswaran A, Sukumar VG. A comparison of canal preparation using the K-file and Light speed in resin blocks. J Endod 1996;22:474-476.
  8. Coleman CL, Suel TA. Analysis of NiTi versus stainless steel instrumentation in resin-simulated canals. J Endod 1997;23: 32-35.
  9. Cohen S, Burns RC. Pathways of the pulp. 7th ed. St. Louis, USA: CV Mosby Co.
  10. Roane JB, Sabala CL, Manville C. The balanced force concept for instrumentation of curved canals. J Endod 1985;11: 203-211.
  11. Walia H, Brantly WA, Gerstein M. An investigation of the bending and torsional properties of Nitinol root canal files. J Endod 1988;14:346-351.
  12. Coleman CL. Analysis of nickel titanium versus stainless steel instrumentation by means of direct digital imaging. J Endod 1996;22:603-607.
  13. Carvalho LAP. A Comparison of molar root canal preparations of six instruments and instrumentation techniques. J Endod 1999;25:807-810.
  14. Glosson CR, Haller RH. A Comparison of root canal preparation using NiTi hand, NiTi engine driven and K-flex endodontic instruments. J Endod 1995;21:146-151.
  15. Shafers S, Versume J. A comparative study of root canal preparation using ProFile 0.04 and Lightspeed rotary NiTi instruments. Int Endodo J 2002;35:37-46.
  16. Harlan AL. A Comparison of curved canal instrumentation using Nickel-Titanium or stainless steel file with the balanced force technique. J Endod 1996;22:410-413.
  17. Short JA. Comparison of canal centering ability of four instrumentation techniques. J Endod 1997;23:503-508.
  18. Royal JR, Donnelly JC. A comparison of maintenance of canal curvature using balanced force instrumentation with three different file types. J Endod 1995;21:300-304.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.