Citation Information :
Chugh A, Arora A, Pratap Singh V. Accuracy of Different Putty-Wash Impression Techniques with Various Spacer Thickness. Int J Clin Pediatr Dent 2012; 5 (1):33-38.
One of the most important steps is accurate impression making for fabrication of fixed partial denture.
The two different putty-wash techniques that are commonly used are: (1) Putty-wash one-step technique, (2) putty-wash two-step technique.
A uniform wash space is needed for an accurate impression. Nissan et al recommended the use of two-step technique for accurate impression making as there is uniform wash space for the light body material to polymerize.
The aim of the present study was to compare the accuracy of stone casts obtained from different putty-wash impression techniques using various spacer thickness.
The critical factor that influences the accuracy of putty-wash impression techniques is the controlled wash bulk which is absent in one-step putty-wash impression technique and with polyethylene spacer was used.
Amorrortu PJ, Brown D. The relative dimensional stability addition cuffed silicone and other elastomeric impression natural. J Dent Res 1979;58:1272.
Beaumont AJ. Proper loading of impression tray minimizes inaccuracies. J Prosthet Dent 2002;88(1):108.
Brown D. An update on elastomeric impression materials. Br Dent J 1981;150(2):35-40.
Chai J, Takahashi Y, Lautenschlager EP. Clinically relevant mechanical properties of elastomeric impression. Int J Prosthodont 1998;11(3):219-223.
Chee WW, Donovan TE. Polyvinyl siloxane impression materials: A review of properties and techniques. J Prosthet Dent 1992;68(5):728-732.
Chong YH, Soh G. Effectiveness of intraoral delivery tips in reducing voids in elastomeric impressions. Quintessence Int 1991;22(11):897-900.
Ciesco JN, Malone WF, Sandrik JL, Mazur B. Comparison of elastomeric impression materials used is fixed prosthodontics. J Prosthet Dent 1981;45(1):89-94.
Craig RG, Urguida NJ, Lui CC. Compares on of commercial elastomeric impression materials used is fixed prosthodontics. Oper Dent 1990;15(3):94-104.
Cullen DR, Sandrik JL. Tensile strength of elastomeric impression materials, adhesive and cohesive bonding. J Prosthet Dent 1989;62(2):142-145.
Dounis GS, Ziebert GJ, Dounis KS. A comparison of impression materials for complete arch fixed partial dentures. J Prosthet Dent 1991;65(2):165-168.
Drummond JL, Randolph RG. Comparative study of elastic impression material. J Prosthet Dent 1986;56(2):188-192.
Eames WB, Wallace SW, Suway NB, Rogers LB. Accuracy and dimensional stability of elastomeric impression materials. J Prosthet Dent 1979;42(2);159-162.
Eames WB, Sieweke JC, Wallace SW, Rogers LB. Elastomeric impression material: Effect of bulk on accuracy. J Prosthet Dent 1979;41(3):304-307.
Gilmore WH, Schnell RJ, Phillips RW. Factors influencing the accuracy of silicone impression materials. J Prosthet Dent 1959; 9(2):304-314.
Gordon GE, Johnson GH, Drennon DG. The effect and tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent 1990;63(1):12-15.
Hung S, Purk JH, Tira DE, Eick JD. Accuracy of one-step versus two-step putty-mash addition silicon impression technique. J Prosthet Dent 1942;67(5):583-589.
Idris B, et al. Comparison of the dimensional accuracy of one and two-step technique with the use of putty-wash addition silicone impression materials. J Prosthet Dent 1995;74(5):535-41.
Johnson GH, Craig RG. Accuracy of four types of rubber impression materials compared with time of pour and repeat pour of models. J Prosthet Dent 1985;53(4):484-490.
Johnson GH, Lepe X, Aw TC. The effect of moisture on detail reproduction of elastomeric impressions. J Prosthet Dent 2003; 90(4):354-364.
Lacy M, Fukui H, Bellman T, Jendresen MD. Time dependent accuracy of elastomer impression materials (part II). Polyether, polysulphides and polyvinyl siloxane. J Prosthet Dent 1981;45: 329-333.
Laufer BZ, Baharav H, Ganor Y, Cardash HS. The effect of marginal thickness on the distortion of different impression materials. J Prosthet Dent 1996;76(5):466-471.
Marcinak CF, Draughn RA. Linear dimensional changes in addition curing silicone impression materials. J Prosthet Dent 1982;47(4):411-413.
Marshak B, Assif D, Pilo R. A controlled putty-wash impression technique. J Prosthet Dent 1990;64(6):635-638.
Millar BJ, Dunne SM, Robinson PB. In vitro study of the number of surface defects in monophase and two-phase addition silicone impressions. J Prosthet Dent 1998;80(1):32-35.
Naylor WP, Beatty MW. Materials and techniques in fixed prosthodontics. Dent Clin North Am 1992;36(3):665-692.
Nissan J, Laufer BZ, Brosh T, Assif D. Accuracy of three polyvinyl siloxane putty-wash impression techniques. J Prosthet Dent 2000;83(2):161-165.
Panichuttra R, Jones RM, Goodacre C, Munoz CA, Moore BK. Hydrophilic poly (vinyl siloxane) impression materials: Dimensional accuracy, wettability and effect on gypsum hardness. Int J Prosthodont 1991;4(3):240-248.
Petersen GF, Asmusssen E. Distortion of impression materials used in the double-mix technique. Scand J Dent Res 1991;99(4):343-348.
Purk JH, Willes MG, Tira DE, Eick JD, Hung SH. The effect of different storage conditions on polyether and polyvinylsiloxane impression. J Am Dent Assoc 1998;129(7):1014-1021.
Ragain, et al. Detail reproduction, contact angels and die hardness of elastomeric impression and gypsum die materials combinations. Int J Prosthodont 2000;13(3):214-220.
Reisbick MH. Effect of viscosity on the accuracy and stability of elastic impression materials. J Dent Res 1973;52(3):407-417.
Reitz CD, Clark NP. The setting of vinyl polysiloxane and condensation silicone putties when mixed with gloved hands. J Am Dent Assoc 1988;116(3):371-374.
Reports of councils and Bureaus. Revised American Dental Association Specification No. 19 for non-aqueous, elastomeric dental impression materials. J Am Dent Assoc 1977;94:733-41.
Robinson PB, Dunne SM, Millar BJ. An in vitro study of a surface wetting agent for addition reaction silicone impressions. J Prosthet Dent 1994;71(4):390-393.
Sandrik JL, Vacco JL. Tensile and bond strength of putty wash elastomeric impression material. J Prosthet dent 1983;50(3):358- 360.
Saunders WP, Sharkey SW, Smith GM, Taylor WG. Effect of impression tray design and impression technique upon the accuracy of stone casts produced from a putty-wash polyvinyl siloxane impression material. J Dent 1991;19(5):283-289.
Schelb E, Mazzocco CV, Jones JD, Prihoda T. Compatibility of type IV dental stone with polyvinyl siloxane impression materials. J Prosthet Dent 1987;58(1):19-22.
Soh G, Chong YH. Defects in automixed addition silicone elastomers prepared by putty wash impression technique. J Oral Rehabilitation 1991;18:547-552.
Stackhouse JA. A comparison of elastic impression materials. J Prosthet Dent 1975;34(3):305-313.
Takahashi H, Finger WJ. Effects of the setting stage on the accuracy of double mix impression made with addition curing silicone. J Prosthet Dent 1994;72(1):78-84.
Tjan AH, Whang SB, Tjan AH, Sarkissian R. Clinically oriented evaluation of the accuracy of commonly used impression materials. J Prosthet Dent 1986;56(1):4-8.
Williams PT, Jackson DG, Bergman W. An evaluation of the time dependent dimensional stability of eleven elastomeric impression materials. J Prosthet Dent 1984;52(1):120-125.